Technical specification
Sustainability Related Features
EV charging stations - Preparation
Building Management System – Yes
Solar panels installation – Building ready for instalation
Floor
Floor loading –70 KN/m2
Floor slab thickness – 16cm
Floor flatness – DIN 18202 table 3, Line 3 equaling 5mm for storage and handling
Structure
Structure material (beams and columns) – Concrete and/or steel
Column grid – 12x24
Clear ceiling height – 12m
Definition: Lowest point of the beam (main beam), with no technical equipment
Wall protection (interiors) – 30cm concrete
Envelope
Wall protection (exterior) – 30cm gravel anti-splash
Insulation: Wall – 200mm Mineral wall
Insulation: Roof – 280mm
Roof membrane – 1,5mm PVC
Roof insulation type – Mineral wool with high compressive strenght
Health & Safety
Sprinkler regulation – local code
ESFR Sprinkler system – K – 14
Smoke/fire alarm system – SK regulation
Roof height safety plans and risk assesment -Implement rict assesment of the roof
-Create roof plan indicating safety features anddangerous areas (e.g. skylight)
Roof access – Ladder with alocker
Fall protection system – Safety points
Exclution zone – 3 meter perimeter or more on the roof if legally required
Technical Installations
Rain water drainage – Siphonic system - insulated
Heating – Gas dark tubes
Minimum temperature in WH – 12°C
Transformer capacity – 630kVa
Technical Installations
Number of dock levelers and dock doors – 1 per 850m2
Dock leveler specks – Electric (2,0m x 2,5m)
Dock door specks – Electric (3,0m x 3,5m)
Lighting - Warehouse
Natural light – Appx. 4% in handling area via skylights
Lighting type – LED
Lighting illuminance – 200 lux in storage , 300 lux in handling area , at 1 m height
Outdoor Area
Car park material – Block paving (concrete or asphalt)
Drive way material – concrete or asphalt
Exterior lighting type – LED
Exterior lighting illuminance – 5 lux (10 lux at front facade or truck court) at 10m distance
Hydrants – By local fire regulation
Landscaping - Grass and trees based on local regulation and GLP standards
Reuse of rainwater for toilet splash/gardening – Yes